SOLAR300N allows carrying out all tests required for the verification of the efficiency of single-phase and three-phase photovoltaic systems. Testing photovoltaic systems requires contemporarily measuring environmental parameters (incident irradiation of modules, temperature of environment and modules) and electric parameters (continuous power, alternating power, etc.).
Typically, modules and inverter can be positioned even at several tens of meters of distance, thus forcing the operator to carry out measurements in different places far from each other at the same time. To carry out these operations, connections by means of long cables or (wireless) radio connections could be necessary, but both these solutions are not acceptable. Cables could hamper the operator’s movements or be a hindrance, while radio waves would be attenuated by floors, reinforced concrete or metal structures, thus making communication impossible.
In order to avoid the above-mentioned problems and to carry out measurements with the necessary contemporaneity, SOLAR300N is provided with a remote unit, synchronized with the main unit. The remote unit is positioned next to the photovoltaic modules and it is connected to the probes for measuring environmental parameters (irradiation and temperature). SOLAR300N is connected upstream and downstream of the inverter in order to acquire the electric parameters (continuous power and alternating power). The synchronization between the two units guarantees the necessary contemporaneity of measurements, the two separate and independent units make measurements comfortable and safe.
SOLAR300N is also a powerful instrument for the complete analysis of mains quality in compliance with standard EN50160 (harmonic analysis, analysis of voltage anomalies, Flicker, unbalance, etc.). The management software TopView also provides the possibility of creating professional reports, which can be customized by adding the company’s logo, the customer’s data, comments, etc.
Learn more by watching the video tutorials!
With this video tutorial will be surprising to discover the ease of use of HT Solar 300N when verifying the efficiency …
- DC/AC TRMS (single-phase and three-phase) current measurement
- DC/AC (single-phase and three-phase) power measurement
- AC (single-phase and three-phase) energy measurement
- DC Measurement of power factor (cosphi) single-phase and three-phase
- Measurement of solar irradiation [W/m2]
- Measurement of temperature by means of probe PT1000
- Recording of voltage and current harmonics up to the 49° order
- Recording of voltage anomalies (dips, peaks)
- Flicker analysis in compliance with standard EN50160
- Recording of starting currents with a resolution of 10ms
- Recording of voltage fast transients (spikes) with a resolution of 5us
- Complete analysis of mains quality in compliance with standard EN50160
- Numerical and graphical display of each quantity
- Recalling results on the display
- TFT colour display with touch screen
- Power supply with rechargeable Li-ION battery
- Memory extension by means of compact flash (CF card)
- Data transfer to external USB memory (memory stick)
- USB port for PC connection
- Help on line at display
Codmetel : HV00300N
Efficiency of single-phase and three-phase photovoltaic systems.
HT SOLAR300N allows carrying out all tests required for the verification of the efficiency of single-phase and three-phase photovoltaic systems. Testing photovoltaic systems requires contemporarily measuring environmental parameters (incident irradiation of modules, temperature of environment and modules) and electric parameters (continuous power, alternating power, etc.)
You’ll always have an OK or NOT OK.
The HT SOLAR300N has been designed to minimize the misinterpretation of data by the user. SOLAR300N for this reason, the instrument will give the user always a positive or negative so as not to unnecessarily spend time in the interpretation data.
Reference Cell HT304N
The Solar 300n has a reference cell that is located next to the photovoltaic module using the appropriate bracket, will measure the solar radiation. This is necessary to calculate the performance of the plant in operating conditions.
There are two types of sensors:
– Monocrystalline
– Polycrystalline
Temperature probe PT300N
The temperature probe will be positioned on the back of the photovoltaic module in order to compensate for the drop in performance of the module as a function of temperature.
Excessive distances?
No problem.
The Solar02 will be synchronized with HT SOLAR300N so you can measure temperature and radiation away from the theinstrument complete the measure simply reconnect via usb to the Solar02 ‘HT SOLAR300N automatically and will exchange all data related to temperature and irradiance measured.
TopView software
In the management of Solar300n software allows the following operations:
√ Creating a professional report for efficiency of single-phase and three-phase photovoltaic systems and on the quality of electricity service (according to EN50160)
√ Analysis of energy consumption for different time slot
√ Creating custom printing reports can also be exported in XLS and PDF.
√ Set the instrument (type of system, recording parameters, etc …)
√ Online display of measured by the instrument (numerical values, waveforms, histograms, sampling instant saving)
√ Start / Stop recording
√ Transfer the data from the instrument to the PC via USB and accurate analysis of the data analysis programmed on the same views on whether numerical / tabular both graphical.
- SOLAR-02 : Remote unit for irradiance/temperature
- KIT800 : Set of 5 cables + 5 alligator clips
- HT4004N : Transducer clamp 10-100A DC
- HT4005K : Rigid clamp 200A AC, diameter 40mm, 3 pcs
- HT304N : Reference cell for radiation measurements
- PT300N : PT1000 probe for cell temperature measurement
- A0055 : External adapter AC/DC recharging battery
- YABAT0003HT0 : Li-ION rechargeable battery
- PT400 : Touch pen
- TOPVIEW2007 : Windows software + USB cable C2007
- VA400 : Rigid carrying case
- User manual on CD-ROM
- Quick reference guide
- ISO9000 calibration certificate
- Alligator clip black, 4 pcs
- HT96U : Rigid clamp 1-100-1000A AC, diameter 54mm
- HT97U : Rigid clamp 10-100-1000A AC, diameter 54mm
- HTFLEX33D : Flex clamp 3000A, for use as analyzer only
- HT98U : Rigid clamp 1000A DC, diameter 50mm
- HP30D1 : Rigid clamp with wide jaws up to 1000A DC
- HT4004P : Rigid clamp 10-100A DC, only for use with MPP300
- HP30C3 : Rigid clamp 3000A AC, diameter 70mm
- HP30C2 : Rigid clamp 200-2000A AC, diameter 70mm
- HT903 : Accessory for connection to external CTs
- SP-0400 : Set of straps for use of meter on neck
- 606-IECN : Connector with magnetic test lead
- ACON3F4M : Adapter for connection of DC clamps to MPP300
EMC 2004/108/CE Directive
CE MARK
EN50160
IEC/EN61000-4-15
IEC/EN61000-4-30 Class B
IEC/EN61187
LVD 2006/95/CE Directive
Reviews